Technical Data
Magnetic flowmeter FLOMAG 3000 is a volume flow rate meter for conductive fluids in pipelines. It allows measurement of flow rates in both directions, with high accuracy and in wide range of flow rates (0,1 – 12 m/s). The microprocessor controlled transmitter offers a wide variety of binary, analogue and digital inputs and outputs suitable for all applications. Absence of moving parts and digital calibration ensures long-term accuracy and stability.
The main benefit of FLOMAG 3000 type series instruments is their versatility. As a standard, the flowmeter transmitter includes a power supply and basic circuits enabling its measuring functions. All other inputs, outputs and display units can be added as plug-in modules. Thus, the customer only pays for the function actually required. This design also permits various inputs and outputs according to the specific needs of the customer
Versions equipped with display and keyboard provides a wide variety of displayable operating data on a readable two-line display with large characters. Also all adjustable parameters can be comfortably changed during operation, using a four-key keyboard.
For communication with transmitter you can use protocols M-BUS, MODBUS-RTU, MODBUS-ASCII or HART. For remote reading you can choose GSM modem.
Transmitter can be integral part of the sensor – compact version or it is connected with the sensor with a cable – remote version. The Transmitters has IP67, sensor up to IP68.
Technical parameters
Power supply | 85..240VAC, 10..36VDC, 24VAC |
---|---|
Consumption | 5..8VA |
Analogue output | optional - A5 - 0(4)..20mA (16bit) - active, A6- 4..20mA (16bit) - active, A7 - 4..20mA (16bit) - passive, all galvanically isolated. Modules A6 and A7 are HART compatible (with module H1) |
Binary output | optional - B1 - 0..1kHz passive, B2 - 0..10kHz passive, B3 - 0..12kHz active (5 V),B3 - 0..12kHz active (24 V), B5 - relay - all galvanically isolated |
Interface | optional - C1- RS232, D1 - RS485 (MODBUS), D2 - 0/20mA loop, D3 - M-Bus, G1 - GSM modem, H1 - HART modem (only with module A6 or A7), P1 - PROFIBUS-DP - all galvanically isolated |
Display | optional - V1 - LCD and keyboard module – 2x16 characters (9,6 mm height) |
Electrode cleaning and pipeline full indication | optional - F1 - electrochemical electrode cleaning module, F2 - pipeline full indication module, F3 = F1+F2 |
Protection | IP66 |
Min conductivity of the liquid | 20μS/cm (for some liquids from 5μS/cm ) |
Attached files
- FLOMAG 3000 Datasheet EN [504 kB]
- F3000 CE Certificate [147 kB]
- F3000 CMI [504 kB]
- FLOMAG3000 Manual EN [1275 kB]
- GSM modul G1 manual EN [424 kB]